No products
New product
Measurements and measurement results are the basis for decisions such as assumptions or rejection of components and parts. Regarding this background, a measurement result must be determined based on the available feature tolerance with minimum uncertainty of measurement. Measuring rooms are instances for well defined and thus known environmental condition, in addition to the measuring equipment itself. They create the prerequisites for well-known and stable environmental conditions and low uncertainty of measurement. The revised standard VDI/VDE 2627 Part 1 describes principles for the planning and operation of measuring rooms. Furthermore parameters are define that are required for planning, establishing and operation of measuring rooms. The standard supports planners, suppliers and operators of measuring rooms when determining the requirements on a measuring room as well as monitoring of compliance with the parameters. Additional, a classification system for test facilities is recommended to assess the performance characteristics of existing measuring rooms and to enable a task-oriented planning of new measuring rooms. The standard applies to measuring rooms for any physical dimension, if necessary, taking into account other parameters. It focuses on the measurement of length. Also the recommended classification applies to rooms for length measurement.
Author | VDI |
---|---|
Editor | VDI |
Document type | Standard |
Format | File |
ICS | 17.040.01 : Linear and angular measurements in general
|
Number of pages | 36 |
Replace | VDI/VDE 2627 Blatt 1 (1998-08) |
Year | 2015 |
Document history | VDI/VDE 2627 Blatt 1 (2015-12) |
Country | Germany |
Keyword | VDI 2627;VDI 2627 Blatt 1;VDI/VDE 2627;2627 |